Accessories for Rotary Phase Converters

Kilogen Modules

On Rotary models it is sometimes practical to use a capacitor (Kilogen) module on one or more large load motors to achieve better voltage and current balance. Connection is by furnished terminal block on all models. This panel connects to an individual motor at the load side of the motor's magnetic starter, and does not affect the normal operation of the rotary converter. Clear instructions furnished

Module Motor Enclosure* KVAR Module Motor Enclosure* KVAR
Model Horsepower Model Horsepower
KG-1 1 R1 1.09 KG-20 20 R3 16.52
KG-2 2 R1 2.17 KG-25 25 R4 20.65
KG-3 3 R1 2.83 KG-30 30 R4 24.78
KG-5 5 R2 5.22 KG-40 40 R4 37.39
KG-7 7.5 R2 7.17 KG-50 50 R5 41.3
KG-10 10 R2 8.26 KG-60 60 R5 49.57
KG-15 15 R3 12.39 KG-75 75 R6 61.96
* NEMA 3R enclosure KG-100 100 R6 82.61

Hard-Start Panels

On some rotary phase converter applications a special panel is required to assist an extremely hard-starting motor. Connection is via terminal block on all models. Clear instructions furnished. These start and run panels will improve performance on any manufacturer's Rotary Phase Converter. If you are having problems with one or more motors on your present converter, consult GWM for connection specifications.

Panel Motor Enclosure* Panel Motor Enclosure*
Model Horsepower Model Horsepower
HS-400 5 R1 HS-2500 30 R5
HS-800 10 R2 HS-3360 40 R5
HS-1200 15 R3 HS-4480 50 R5
HS-1680 20 R3 HS-5600 60 R6
HS-1960 25 R4 HS-6160 75 R6
* NEMA 3R enclosure HS-7280 100 2-R6

Line-TamerTM Soft-Starting Option for Rotary Converters

Some electrical utility companies place restrictions on the largest motor-type load you are allowed to start on their single-phase line. The rotary converter is a motor generator and larger models can cause line disturbance when started. Our Line-TamerTM option allows the rotary to attain operating speed at only 33% of the normal current inrush required for comparable across-the-line start models. A timer automatically shifts the rotary into its full-power run mode before loads are introduced. Uses generic, dependable wye start/delta run motor technology to operate. Includes one each start and run mode DP contactors, timer and necessary auxiliary components factory-installed on your converter and ready to operate. This converter does not use electrolytic motor-starting capacitors. This option does not include main magnetic starter to switch the rotary off/on. Main magnetic starter with fusing is also available